Wherever heat or cold can penetrate a building from outside, PUR/PIR insulation ensures higher comfort and lower energy costs. Thanks to the low thermal conductance of PUR/PIR, the panel construction remains slim, with more useful space as a result. Smaller heating and cooling systems can be installed, as less heat is required in winter, and the need for cooling in summer is greatly reduced.
PUR/PIR is pressure and temperature resistant, insensitive to moisture, dimensionally accurate & stable, non-ageing, and does not rot. The insulating panels are light, and can be cut and processed with standard woodworking tools and machines. PUR/PIR has a positive building biology.
LINIT composite panels with a PUR/PIR insulating core are available with facings of aluminium, steel, glass, wood, plastic, laminate and fibre cement.
LINITHERM PAL | ||||||
Insulation core: | PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides | |||||
Edge joints: | Thickness 20 – 40 mm: blunt cut on all sides, Thickness 50 – 100 mm and 200 mm: blunt cut on all sides or with rabbet edges, Thickness 120 – 240 mm: rabbet edges on all sides. | |||||
Coverage: | 1200 x 600 mm (for calculation) | |||||
(coverage is 2 cm less with rabbet edges) | ||||||
Thickness (mm) | Package contents | Pallet contents | TCL | U-value 1 | ||
total | Quantity | m² | Quantity | m² | PIR | [W/(m²K)] |
20 | 25 | 18 | 250 | 180 | 22 | 0,95 |
30 | 16 | 11,52 | 160 | 115,2 | 22 | 0,67 |
40 | 12 | 8,64 | 120 | 86,4 | 22 | 0,51 |
50 | 10 | 7,2 | 100 | 72 | 22 | 0,41 |
60 | 8 | 5,76 | 80 | 57,6 | 22 | 0,35 |
70 | 7 | 5,04 | 70 | 50,4 | 22 | 0,3 |
80 | 6 | 4,32 | 60 | 43,2 | 22 | 0,27 |
100 | 5 | 3,6 | 50 | 36 | 22 | 0,21 |
120 | 4 | 2,88 | 40 | 28,8 | 22 | 0,18 |
140 | 3 | 2,16 | 30 | 21,6 | 22 | 0,15 |
160 | 3 | 2,16 | 30 | 21,6 | 22 | 0,14 |
180* | 2 | 1,44 | 28 | 20,2 | 22 | 0,12 |
200* | 2 | 1,44 | 24 | 17,3 | 22 | 0,11 |
220* | 2 | 1,44 | 20 | 14,4 | 22 | 0,1 |
240* | 2 | 1,44 | 20 | 14,4 | 22 | 0,09 |
* Longer delivery time. |
LINITHERM PGV | ||||||
Insulation core: | PIR rigid foam acc. to DIN EN 13165, class E, with mineral fleece on both sides | |||||
Edge joints: | Thickness 20 – 40: blunt cut on all sides. Thickness 50-100 mm and 200 mm: blunt cut on all sides or with rabbet edges. Thickness 120-240 mm: rabbet edges on all sides. | |||||
Coverage: | 1200 x 600 mm (for calculation) | |||||
(coverage is 2 cm less with rabbet edges) | ||||||
Thickness (mm) | Package contents | Pallet contents | TCL | U-value 1 | ||
total | Quantity | m² | Quantity | m² | PIR | [W/(m²K)] |
20 | 25 | 18 | 250 | 180 | 28 | 1,17 |
30 | 16 | 11,52 | 160 | 115,2 | 28 | 0,83 |
40 | 12 | 8,64 | 120 | 86,4 | 28 | 0,64 |
50 | 10 | 7,2 | 100 | 72 | 28 | 0,52 |
60 | 8 | 5,76 | 80 | 57,6 | 28 | 0,44 |
80 | 6 | 4,32 | 60 | 43,2 | 26 | 0,31 |
100 | 5 | 3,6 | 50 | 36 | 26 | 0,25 |
120 | 4 | 2,88 | 40 | 28,8 | 25 | 0,2 |
140 | 3 | 2,16 | 30 | 21,6 | 25 | 0,17 |
160 | 3 | 2,16 | 30 | 21,6 | 25 | 0,15 |
180* | 2 | 1,44 | 28 | 20,2 | 25 | 0,14 |
200* | 2 | 1,44 | 24 | 17,3 | 25 | 0,12 |
220* | 2 | 1,44 | 20 | 14,4 | 25 | 0,11 |
240* | 2 | 1,44 | 20 | 14,4 | 25 | 0,1 |
* Longer delivery time |
TCL – Thermal Conductivity Level |
1 U-value, taking the thermal transfer resistance Rsi = 0.1 [m²K/W] and Rse = 0.04 [m²K/W] into account. Object-specific features acc. to DIN EN ISO 6946 are not taken into account |