(+372) 517 9107 (+372) 58 868 956

LINIT Metal panels

 Metal 1

 

LINIT Panels with metal surfaces for modern facades, wall elements and partition wall elements, for cooling, ventilation and dry construction. Surfaces made of aluminium, steel, brass or copper. Smooth surface, embossed surfaces, textured surfaces, anodised or varnished surfaces, flat or curved surfaces. With an insulation core of PUR/PIR rigid foam, respectively vacuum insulation panels (VIP), the elements achieve maximum insulation values with minimal panel thickness. Linit Metal panel elements fullfil the requirements of fire protection classes up to W90 and achieve a sound insulation up to 50 dB. With an additional bulletproof layer the building is made a safe place.

Advantages:

  • Thermal insulation, fire and sound protection
  • Simple handling – quick assembly
  • Suitable for all stick system curtain walls
  • Easy to clean, weather and temperature resistant

Application areas:

  • Balustrade and facade elements
  • Wall and partition wall elements
  • Tailored solutions for free space in planning and creative design

 

EDGE DESIGN

 

  LINIT ALYAL LINIT VIP LINIT ALMST
Insulation core: PUR/PIR rigid foam micro-porous vacuum insulation core mineral fibre insulation
panels
Density: approx. 33 kg/m3 approx. 160 – 180 kg/m3 65 kg/m3
Thermal conductivity
(in accordance with DIN 4108)
0.029 W/(mK) < 80 mm
0.028 W/(mK) 80 – 119 mm
0.027 W/(mK) > 120 mm
0.008 W/(mK) 0.035 W/(mK)
Face sheets: aluminium sheet, electrolytic galvanised steel sheets
Colours: anodised or powder-coated according to RAL/NCS
Building materials class
insulation core :
(in accordance with DIN 4102)
B2 B2 A1
Sound insulation dB: 27 – 30 30 – 33 37 – 48
Edges: various design
Format/Panel thickness: customised
Thickness mm
PUR/PIR
U-value *
W/(m²K)
Thickness mm
vacuum insulation core
U-value *
W/(m²K)
Thickness mm
mineral fibres
U-value *
W/(m²K)
40 0,65 20 0,37 40 0,76
60 0,45 24 0,32 60 0,53
80 0,33 26 0,29 80 0,41
100 0,27 30 0,26 100 0,33
120 0,22 35 0,22 120 0,28
* U-value calculation of the undisturbed panel W/(m2K) without taking into consideration the edge area and the frame construction.