(+372) 517 9107 (+372) 58 868 956

LINIT KSK plastic

Linit KSK

 

LINIT KSK
Insulation core: extruded rigid Polystyrene foam regarding EN 13164
Thermal conductivity
(in accordance with DIN 4108)
0.034 W/(mK)
Face sheets: hard PVC 1,5 or 2 mm, UV-resistant
Building materials class
insulation core :
(in accordance with DIN 4102)
B1
Format/Panel thickness: standard dimensions: 3000*1500 mm; 1000*2000 mm; 23mm and 24 mm
Thickness mm
total
Thickness mm
insulation core
U-value *
W/(m²K)
23 20 1,3
24 20 1,28
* U-value calculation of the undisturbed panel W/(m2K) without taking into consideration the edge area and the frame construction.
Alternative dimensions available on request.