PUR/PIR – slim, but high insulation
Wherever heat or cold can penetrate a building from outside, PUR/PIR insulation ensures higher comfort and lower energy costs. Thanks to the low thermal conductance of PUR/PIR, the panel construction remains slim, with more useful space as a result. Smaller heating and cooling systems can be installed, as less heat is required in winter, and the need for cooling in summer is greatly reduced.
PUR/PIR is pressure and temperature resistant, insensitive to moisture, dimensionally accurate & stable, non-ageing, and does not rot. The insulating panels are light, and can be cut and processed with standard woodworking tools and machines. PUR/PIR has a positive building biology.
LINIT composite panels with a PUR/PIR insulating core are available with facings of aluminium, steel, glass, wood, plastic, laminate and fibre cement.
| LINITHERM PAL | ||||||
| Insulation core: | PIR rigid foam acc. to DIN EN 13165, class E, aluminium foil on both sides | |||||
| Edge joints: | Thickness 20 – 40 mm: blunt cut on all sides, Thickness 50 – 100 mm and 200 mm: blunt cut on all sides or with rabbet edges, Thickness 120 – 240 mm: rabbet edges on all sides. | |||||
| Coverage: | 1200 x 600 mm (for calculation) | |||||
| (coverage is 2 cm less with rabbet edges) | ||||||
| Thickness (mm) | Package contents | Pallet contents | TCL | U-value 1 | ||
| Quantity | m² | Quantity | m² | PIR | [W/(m²K)] | |
| 20 | 25 | 18 | 250 | 180 | 22 | 0,95 | 30 | 16 | 11,52 | 160 | 115,2 | 22 | 0,67 |
| 40 | 12 | 8,64 | 120 | 86,4 | 22 | 0,51 |
| 50 | 10 | 7,2 | 100 | 72 | 22 | 0,41 |
| 60 | 8 | 5,76 | 80 | 57,6 | 22 | 0,35 |
| 70 | 7 | 5,04 | 70 | 50,4 | 22 | 0,3 |
| 80 | 6 | 4,32 | 60 | 43,2 | 22 | 0,27 |
| 100 | 5 | 3,6 | 50 | 36 | 22 | 0,21 |
| 120 | 4 | 2,88 | 40 | 28,8 | 22 | 0,18 |
| 140 | 3 | 2,16 | 30 | 21,6 | 22 | 0,15 |
| 160 | 3 | 2,16 | 30 | 21,6 | 22 | 0,14 |
| 180* | 2 | 1,44 | 28 | 20,2 | 22 | 0,12 |
| 200* | 2 | 1,44 | 24 | 17,3 | 22 | 0,11 |
| 220* | 2 | 1,44 | 20 | 14,4 | 22 | 0,1 |
| 240* | 2 | 1,44 | 20 | 14,4 | 22 | 0,09 |
| * Longer delivery time. |
||||||
| LINITHERM PGV | ||||||
| Soojustusmaterjal: | PIR soojustusplaat vastavalt DIN EN 13165, klass E, külgedel mineraalne fliis | |||||
| Edge joints: | Thickness 20 – 40 mm: blunt cut on all sides, Thickness 50 – 100 mm and 200 mm: blunt cut on all sides or with rabbet edges, Thickness 120 – 240 mm: rabbet edges on all sides. | |||||
| Coverage: | 1200 x 600 mm (for calculation) | |||||
| (coverage is 2 cm less with rabbet edges) | ||||||
| Thickness (mm) | Package contents | Pallet contents | TCL | U-VALUE 1 | ||
| Quantity | m² | Quantity | m² | PIR | [W/(m²K)] | |
| 20 | 25 | 18 | 250 | 180 | 28 | 1,17 |
| 30 | 16 | 11,52 | 160 | 115,2 | 28 | 0,83 |
| 40 | 12 | 8,64 | 120 | 86,4 | 28 | 0,64 |
| 50 | 10 | 7,2 | 100 | 72 | 28 | 0,52 |
| 60 | 8 | 5,76 | 80 | 57,6 | 28 | 0,44 |
| 80 | 6 | 4,32 | 60 | 43,2 | 26 | 0,31 |
| 100 | 5 | 3,6 | 50 | 36 | 26 | 0,25 |
| 120 | 4 | 2,88 | 40 | 28,8 | 25 | 0,2 |
| 140 | 3 | 2,16 | 30 | 21,6 | 25 | 0,17 |
| 160 | 3 | 2,16 | 30 | 21,6 | 25 | 0,15 |
| 180* | 2 | 1,44 | 28 | 20,2 | 25 | 0,14 |
| 200* | 2 | 1,44 | 24 | 17,3 | 25 | 0,12 |
| 220* | 2 | 1,44 | 20 | 14,4 | 25 | 0,11 |
| 240* | 2 | 1,44 | 20 | 14,4 | 25 | 0,1 |
| * Longer delivery time |
| TCL – Thermal Conductivity Level |
| 1 U-value, taking the thermal transfer resistance Rsi = 0.1 [m²K/W] and Rse = 0.04 [m²K/W] into account. Object-specific features acc. to DIN EN ISO 6946 are not taken into account |